8 C
United Kingdom
Saturday, April 26, 2025

7 Steps For an Straightforward DIY


Are you uninterested in stepping out of your bathe and coping with limitless moisture in your lavatory? Though it might solely look like a minor inconvenience, an excessive amount of moisture within the lavatory could cause harm, or worse, can result in mildew. Putting in (or changing) a rest room exhaust fan is the best answer to assist mitigate your moisture points as a result of it helps to take away moisture, warmth, and odors from the area.

Though putting in a rest room exhaust fan isn’t the best of do-it-yourself initiatives, it’s doable so that you can do it your self with the correct instruments and plan of motion. There’s no must be nervous about taking over this undertaking by yourself. That will help you really feel assured putting in a rest room exhaust fan, Kitchen Cupboard Kings has supplied you with step-by-step directions outlining seven obligatory steps to make sure a seamless set up.

Step 1: Mark the Location of the Fan

Individual marking ceiling where to install exhaust fan.

In the event you don’t have an current lavatory exhaust fan that you’re changing, you’ll need to find out the place on the ceiling you intend to put in the brand new exhaust fan. Relying on the prevailing lighting in your lavatory, you’ll be able to go for a twin mild and exhaust fan or a separate exhaust fan throughout your lavatory transform. Nonetheless, if you’re doing a separate exhaust fan you should set up it close to the prevailing mild fixture as a result of it would take energy from the sunshine fixture’s wiring.

To find out the correct ceiling placement close to the sunshine fixture, use a stud finder to find the joists within the ceiling. Your exhaust fan needs to be positioned immediately between the 2 joists to make sure its weight is supported. When you’ve decided the place you need to set up the toilet fan, frivolously hint the fan on the ceiling so you recognize precisely the place you should reduce.

Step 2: Minimize an Opening for the Fan

Cutting hole in ceiling with drywall saw.

Now that you recognize the place you intend to put in the exhaust fan, it’s time to chop a gap within the ceiling the place it would go. Nonetheless, you should be certain {the electrical} is reduce off to the grasp lavatory earlier than starting this step to forestall the chance of electrocution should you hit a wire within the ceiling. Utilizing your electrical circuit breaker, flip off the circuit that gives mild to your lavatory. As soon as the ability is turned off, you’ll be able to start utilizing your drill to make small holes on every nook of the traced define to make the chopping course of a bit simpler. Then, use a drywall noticed to chop from nook to nook and take away the drywall to disclose the opening the place the exhaust fan might be positioned.

Step 3: Set up a Air flow Duct

Connecting the ventilation hose from the exhaust fan to the exterior vent.

The aim of putting in a rest room exhaust fan is so as to add air flow to the area, permitting warmth and moisture to correctly dissipate. This implies that you could’t simply place the fan within the ceiling and anticipate it to work ? you should set up a air flow duct for the ceiling fan so it may correctly funnel warmth and moisture out of your house. In most cases, it’s finest to have the ceiling fan vented by means of a roof vent.

For the air flow duct, we suggest utilizing a versatile aluminum hose that’s roughly 4? in diameter (except in any other case laid out in your exhaust fan set up package). After you have your provides, look by means of the opening that you just reduce within the ceiling to search out the closest exterior wall. Transfer the hose into the area and modify it till it reaches the doorway to the ceiling and the outside wall.

Step 4: Minimize a Gap for the Exterior Vent

Applying caulk to edge of exterior ventilation hole for exhaust fan.

Subsequent, you’ll want to securely make your method to your roof bringing a vent cap and instruments, similar to a reciprocating noticed, cordless drill, and silicone caulk. Utilizing the noticed, reduce a small gap within the roof the place you lined up the hose. As soon as the opening is made, you’ll be able to connect the vent cap with screws after which define it with the silicone caulk to forestall any water from leaking into your house.

Step 5: Connect the Exhaust Fan to the Joists

Installing the exhaust fan to the ceiling joists.

Subsequent, it’s time to connect the exhaust fan in place. Head to the attic and hoist the fan into the opening you created within the drywall so it’s flush with the ceiling and fasten it to the joists. We suggest having a member of the family or good friend help with this step as it may be tough to get it correctly in place and screw it in on the similar time.

Step 6: Make Electrical Connections

Wiring the exhaust fan to the existing light fixture.

Earlier than leaving the attic, join the air flow hose from the bottom of the ceiling fan to the vent cap within the roof, guaranteeing the correct circulation of moisture out of your lavatory. Then, it’s time to make the electrical connections for the brand new exhaust fan.

Observe: should you don’t need the fan to activate with the sunshine, you’ll need to replace the wiring and set up a double change. To do that, run a 3-wire cable from the brand new exhaust fan to the prevailing change and swap out the previous change for a double change within the electrical field.

As soon as the double change has been put in, it’s time to attach the exhaust fan wiring to the prevailing ceiling fixture wiring. Use 12/2 electrical wire and twist one finish with the black and white wires of the fan unit. Then, hook up the black and white wires on the different finish of the cable to the matching wires on the sunshine fixture to energy your exhaust fan.

Step 7: Flip the Circuit Breaker On

Adding faceplate of exhaust fan to the ceiling.

After the exhaust fan is wired, add the fan grill plate to the face of the exhaust fan. Then, you’ll be able to flip in your circuit breaker to revive electrical energy to the toilet. Flip the change for the fan and revel in a moisture-free lavatory.

Regularly Requested Questions

Do lavatory exhaust followers must be vented outdoors?

It is strongly recommended to have a rest room exhaust fan vent outdoors when doable. Nonetheless, it doesn’t must be by means of your ceiling/roof if that’s not possible with the situation of your lavatory. You may set up a vent within the sidewall of your house with a wall-mounted exhaust fan.

Is a rest room exhaust fan required?

You do not want a rest room exhaust fan. Nonetheless, an exhaust fan works to maintain your lavatory correctly ventilated as a result of quantity of moisture it experiences. If the moisture has nowhere to go, you might end up with lavatory odors, mildew, and mildew that may be remedied by vegetation.

How do you vent a rest room with no outdoors entry?

Generally your lavatory might not have entry to an exterior vent. If the situation of your lavatory is in the course of your house and it solely has inner partitions, you’ll be able to set up a central exhaust fan that helps funnel the air outdoors by means of air flow shafts.

When ought to I activate a rest room exhaust fan?

You do not want to go away your lavatory exhaust fan turned on on a regular basis. As a substitute, we suggest utilizing it when having a shower or bathtub ? or doing something that introduces a number of moisture within the air. Overusing your fan will use extra power and may end up in a dearer power invoice.

Andrew Saladino

Andrew Saladino is the Co-Founding father of Kitchen Cupboard Kings the place he has helped over 10,000 prospects with their transforming initiatives. He’s a nationally awarded kitchen and toilet skilled by the NKBA and his recommendation has been featured in main publications similar to Forbes, Huffington Submit, Mashable, Yahoo! Small Enterprise, and extra.